<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Gorgan University of Medical Sciences</title>
<title_fa>مجله علمي دانشگاه علوم پزشكي گرگان</title_fa>
<short_title>J Gorgan Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://goums.ac.ir/journal</web_url>
<journal_hbi_system_id>59</journal_hbi_system_id>
<journal_hbi_system_user>journal58</journal_hbi_system_user>
<journal_id_issn>1562-4765</journal_id_issn>
<journal_id_issn_online>2008-4080</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/goums</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1404</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2025</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>27</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی میزان توافق دستگاه تصویربرداری جستجوگر قرنیه پیشرفته با پنتاکم و اورب اسکن در افراد نزدیک بین با قرنیه سالم</title_fa>
	<title>Evaluation of the Agreement of Advanced Corneal Explorer with Pentacam and Orbscan in Myopic Individuals with Healthy Corneas</title>
	<subject_fa>چشم پزشكي</subject_fa>
	<subject>Ophtalmology</subject>
	<content_type_fa>تحقيقي</content_type_fa>
	<content_type>Original Articles</content_type>
	<abstract_fa>&lt;p style=&quot;font-style:normal;&quot;&gt;&lt;span style=&quot;color:#003300;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;line-height:16.0pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; بررسی توافق دستگاه&#8204;های تصویربرداری قرنیه به&#8204;دلیل تکنولوژی&#8204; متفاوت در این دستگاه&#8204;ها در تشخیص پارامترهای قرنیه بسیار مهم است. این مطالعه به منظور ارزیابی میزان توافق دستگاه تصویربرداری جستجوگر قرنیه &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;(Advanced Corneal Explorer: ACE)&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; پیشرفته با پنتاکم و اورب اسکن در افراد نزدیک بین با قرنیه سالم انجام شد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;br&gt;
&lt;span style=&quot;line-height:16.0pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; این مطالعه توصیفی تحلیلی روی 45 فرد نزدیک&#8204;بین (25 زن و 20 مرد) با میانگین سنی &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;6.13&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&amp;plusmn;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;30.37&lt;/span&gt; سال مراجعه کننده به بیمارستان چشم پزشکی الزهراء زاهدان طی سال 1402 انجام شد. تصویربرداری سگمان قدامی با سه دستگاه &lt;span dir=&quot;LTR&quot;&gt;ACE&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;، پنتاکم و ارب اسکن انجام شد. پارامترهای قرنیه شامل توپوگرافی، توموگرافی و ابیراهی&#8204;های قرنیه بررسی شدند. برای بررسی توافق داده&#8204;های &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ACE&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; با دو دستگاه دیگر از ضریب همبستگی درون کلاسی&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ICC&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; و حدود توافق 95 درصد استفاده شد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;br&gt;
&lt;span style=&quot;line-height:16.0pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;strong&gt;یافته&#8204;ها:&lt;/strong&gt; دستگاه &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ACE&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; با پنتاکم در میانگین قدرت &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;(ICC=0.97)&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;، قدرت حداکثر &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;(ICC=0.98)&lt;/span&gt; و قدرت حداقل سطح قدام &lt;span dir=&quot;LTR&quot;&gt;(ICC=0.97)&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; قرنیه توافق خوبی را نشان داد (&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;P&lt;0.05&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;). همچنین &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ACE&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; با ارب اسکن در میانگین قدرت سطح قدام قرنیه به&#8204;دلیل &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ICC&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; برابر با &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;0.98&lt;/span&gt; توافق آماری خوبی را نشان داد (&lt;span dir=&quot;LTR&quot;&gt;P&lt;0.05&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;). &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ICC&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; برای ضخامت مرکزی و نازکترین ضخامت قرنیه با دو دستگاه &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ACE&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; و پنتاکم به ترتیب &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;0.99&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; و &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;0.95&lt;/span&gt; به&#8204;دست آمد که توافق آماری با اهمیتی را نشان داد (&lt;span dir=&quot;LTR&quot;&gt;P&lt;0.05&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;). فاصله وایت تو وایت، سایز مردمک و ابیراهی&#8204;های قرنیه توافق خوبی را بین سه دستگاه نشان ندادند &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;(ICC&lt;0.75)&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;br&gt;
&lt;span style=&quot;line-height:16.0pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;strong&gt;نتیجه&#8204;گیری: &lt;/strong&gt;مقادیر توپوگرافی و ضخامت قرنیه اندازه گیری شده با &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ACE&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; توافق خوبی با پنتاکم داشتند؛ لذا قابل جایگزینی با یکدیگرند. سایر متغیرهای اندازه&#8204;گیری شده &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ACE&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; با پنتاکم و ارب اسکن توافق خوبی نداشتند و قابل جایگزینی با یکدیگر نیستند.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;font-style:normal;&quot;&gt;&lt;span style=&quot;color:#003300;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;b&gt;Background and Objective:&lt;/b&gt; Evaluating the agreement among various corneal imaging devices is crucial due to their varying technologies in diagnosing corneal parameters. This study aimed to assess the agreement of Advanced Corneal Explorer (ACE) with Pentacam and Orbscan in myopic individuals with healthy corneas.&lt;br&gt;
&lt;b&gt;Methods:&lt;/b&gt; This descriptive-analytical study was conducted on 45 myopic individuals (25 women and 20 men; mean age=30.37&amp;plusmn;6.13 years) referring to Al-Zahra Ophthalmology Hospital in Zahedan, Iran, during 2023. Anterior segment imaging was performed using three devices: ACE, Pentacam, and Orbscan. Corneal parameters, including topography, tomography, and corneal aberrations, were examined. The intraclass correlation coefficient (ICC) and 95% limits of agreement (LoA) were used to evaluate the agreement of ACE data with the data obtained from the other two devices.&lt;br&gt;
&lt;b&gt;Results:&lt;/b&gt; ACE exhibited good agreement with Pentacam for the mean power (ICC=0.97), maximum power (ICC=0.98), and minimum power of the anterior corneal surface (ICC=0.97) (P&lt;0.05). Additionally, ACE exhibited good statistical agreement with Orbscan for the mean power of the anterior corneal surface due to an ICC of 0.98 (P&lt;0.05). The ICC values for central corneal thickness and thinnest corneal thickness with the ACE and Pentacam devices were 0.99 and 0.95, respectively, indicating significant statistical agreement (P&lt;0.05). White-to-white distance, pupil size, and corneal aberrations did not show good agreement among the three devices (ICC&lt;0.75).&lt;br&gt;
&lt;b&gt;Conclusion:&lt;/b&gt; Topography values and corneal thickness measured with ACE showed good agreement with Pentacam; therefore, they can be used interchangeably. Other measured variables from ACE did not show good agreement with Pentacam and Orbscan and are not interchangeable.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract>
	<keyword_fa>قرنیه , توپوگرافی قرنیه , ارب سکن</keyword_fa>
	<keyword>Cornea,Corneal Topography,Myopia,</keyword>
	<start_page>50</start_page>
	<end_page>60</end_page>
	<web_url>http://goums.ac.ir/journal/browse.php?a_code=A-10-25-6&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammad-Hosein </first_name>
	<middle_name></middle_name>
	<last_name>Validad </last_name>
	<suffix></suffix>
	<first_name_fa>محمدحسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ولیداد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>5900319475328460082919</code>
	<orcid>5900319475328460082919</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Ophthalmologist, Department of Ophthalmology, Alzahra Eye Hospital, Zahedan University of Medical Sciences, Zahedan, Iran.</affiliation>
	<affiliation_fa>استادیار، فوق تخصص چشم، گروه چشم پزشکی، بیمارستان چشم پزشکی الزهرا، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Hava </first_name>
	<middle_name></middle_name>
	<last_name>Shafiee </last_name>
	<suffix></suffix>
	<first_name_fa>حوا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شفیعی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shafiee66h@yahoo.com</email>
	<code>5900319475328460082920</code>
	<orcid>5900319475328460082920</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>M.Sc in Optometry, Department of Optometry, School of Rehabilitation Sciences, Zahedan University of Medical Sciences, Zahedan, Iran.</affiliation>
	<affiliation_fa>فوق لیسانس اپتومتری، گروه اپتومتری، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Monireh </first_name>
	<middle_name></middle_name>
	<last_name>Mahjoob </last_name>
	<suffix></suffix>
	<first_name_fa>منیره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محجوب</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mahjoob_opt@yahoo.com</email>
	<code>5900319475328460082921</code>
	<orcid>5900319475328460082921</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Ph.D in Optometry, Department of Optometry, School of Rehabilitation Sciences, Zahedan University of Medical Sciences, Zahedan, Iran.</affiliation>
	<affiliation_fa>دانشیار، دکتری تخصصی، گروه اپتومتری، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Tahereh </first_name>
	<middle_name></middle_name>
	<last_name>Rakhshandadi </last_name>
	<suffix></suffix>
	<first_name_fa>طاهره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رخشان دادی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>rakhshandt991@mums.ac.ir</email>
	<code>5900319475328460082922</code>
	<orcid>5900319475328460082922</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Ph.D in Optometry, Department of Optometry, School of Rehabilitation Sciences, Zahedan University of Medical Sciences, Zahedan, Iran.</affiliation>
	<affiliation_fa>دانشیار، دکتری تخصصی، گروه اپتومتری، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Hadi </first_name>
	<middle_name></middle_name>
	<last_name>Ostadimoghaddam </last_name>
	<suffix></suffix>
	<first_name_fa>هادی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>استادی مقدم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ostadih@mums.ac.ir</email>
	<code>5900319475328460082923</code>
	<orcid>5900319475328460082923</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Professor, Ph.D in Optometry, Refractive Error Research Center, Department of Optometry, School of Rehabilitation Sciences, Mashhad University of Medical Sciences, Mashhad, Iran.</affiliation>
	<affiliation_fa>استاد، دکتری تخصصی، مرکز تحقیقات عیوب انکساری، گروه اپتومتری، دانشکده پیراپزشکی و علوم توانبخشی، دانشگاه علوم پزشکی مشهد، مشهد، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Abbas-Ali </first_name>
	<middle_name></middle_name>
	<last_name>Yekta </last_name>
	<suffix></suffix>
	<first_name_fa>عباسعلی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یکتا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>yektaa@mums.ac.ir</email>
	<code>5900319475328460082924</code>
	<orcid>5900319475328460082924</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Professor, Ph.D in Optometry, Refractive Error Research Center, Department of Optometry, School of Rehabilitation Sciences, Mashhad University of Medical Sciences, Mashhad, Iran.</affiliation>
	<affiliation_fa>استاد، دکتری تخصصی، مرکز تحقیقات عیوب انکساری، گروه اپتومتری، دانشکده پیراپزشکی و علوم توانبخشی، دانشگاه علوم پزشکی مشهد، مشهد، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Javad </first_name>
	<middle_name></middle_name>
	<last_name>Heravian Shandiz </last_name>
	<suffix></suffix>
	<first_name_fa>جواد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هرویان شاندیز</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>heraviansj@mums.ac.ir</email>
	<code>5900319475328460082925</code>
	<orcid>5900319475328460082925</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Professor, Ph.D in Optometry, Refractive Error Research Center, Department of Optometry, School of Rehabilitation Sciences, Mashhad University of Medical Sciences, Mashhad, Iran.</affiliation>
	<affiliation_fa>استاد، دکتری تخصصی، مرکز تحقیقات عیوب انکساری، گروه اپتومتری، دانشکده پیراپزشکی و علوم توانبخشی، دانشگاه علوم پزشکی مشهد، مشهد، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Neda </first_name>
	<middle_name></middle_name>
	<last_name>Nakhjavanpour </last_name>
	<suffix></suffix>
	<first_name_fa>ندا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نخجوان پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>neda.nakhjavanpoor@gmail.com</email>
	<code>5900319475328460082926</code>
	<orcid>5900319475328460082926</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>M.Sc in Optometry, Department of Optometry, School of Rehabilitation Sciences, Zahedan University of Medical Sciences, Zahedan, Iran.</affiliation>
	<affiliation_fa>فوق لیسانس اپتومتری، گروه اپتومتری، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Sara </first_name>
	<middle_name></middle_name>
	<last_name>Farsi </last_name>
	<suffix></suffix>
	<first_name_fa>سارا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فارسی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sa.farsi1995@gmail.com</email>
	<code>5900319475328460082927</code>
	<orcid>0009-0004-4406-9891</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>M.Sc in Optometry, Department of Optometry, School of Rehabilitation Sciences, Zahedan University of Medical Sciences, Zahedan, Iran.</affiliation>
	<affiliation_fa>فوق لیسانس اپتومتری، گروه اپتومتری، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
